FESTO
FESTO Valve terminal VTUG-10-VRLK-B1T-Q10B-UB-QH6SU-8K+TVSC 573606
$1.00
+ Free Shipping- Electrical controlAP interface Individual connection Fieldbus I-Port IO-Link® Multi-pin
- Electrical I/O systemNo
- Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
- Pilot mediumCompressed air to ISO 8573-1:2010 [7:4:4]
- Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will always be required)
- Media temperature-5 °C … 60 °C
- Ambient temperature-5 °C … 60 °C
- Storage temperature-10 °C … 60 °C
- Degree of protectionIP40 IP65 IP67 IP69K NEMA 4X
- Corrosion resistance class CRC2 – Moderate corrosion stress
- Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN 60068-2-6
- Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
- Operating pressure-0.09 MPa … 1 MPa
- Operating pressure-0.9 bar … 10 bar
- Pilot pressure0.15 MPa … 0.8 MPa
- Pilot pressure1.5 bar … 8 bar
- Operating pressure for valve terminal with internal pilot air supply1.5 bar … 8 bar
- LABS (PWIS) conformityVDMA24364-B1/B2-L
- Cleanroom suitability, measured according to ISO 14644-14Class 5 according to ISO 14644-1
- CE mark (see declaration of conformity)In accordance with EU RoHS Directive
- UKCA marking (see declaration of conformity)To UK RoHS instructions
- KC markKC-EMV
- ApprovalRCM c UL us – Recognised (Oil)
- Certificate issuing authorityUL MH19482
- Note on materialsRoHS compliant
- Material sealsHNBR NBR
- Valve terminal structureFixed grid
- Max. number of valve positions24
- Max. number of pressure zones13
- Valve function2×3/2 closed monostable 2×3/2 open monostable 2×3/2-way, open/closed, monostable 3/2-way, single solenoid, closed 3/2-way, single solenoid, open 5/2-way, double solenoid 5/2-way, single solenoid 5/3-way, pressurised 5/3 exhausted 5/3-way, closed
- Type of actuationElectrical
- DesignPiston gate valve
- Sealing principleSoft
- Type of pilotingPiloted
- Valve size18 mm
- Pilot air supplyExternal Internal
- Max. standard nominal flow rate330 l/min at 10 mm 630 l/min at 14 mm 1200 l/min at 18 mm
- Standard nominal flow rate (standardised to DIN 1343)130 l/min … 1150 l/min
- Suitability for vacuumYes
- Exhaust-air functionCan be throttled
- pneumatic working portM5 M7 G1/8 G1/4 QS-3 QS-4 QS-6 QS-8 QS-10 QS-5/32 QS-1/8 QS-3/16 QS-1/4 QS-5/16 QS-3/8
- Pneumatic connection, port 1QS-16 QS-1/4 QS-5/16 QS-3/8 QS-1/2
- Pilot air port 12/14G1/8
- Signal status displayLED
- Nominal operating voltage DC24 V
- Permissible voltage fluctuations+/-10% +/-25%
- Nominal pick-up current per solenoid coil47 mA to 20 ms
- Nominal current with current reduction15.5 mA after 20 ms
SKU: 00129
Category: FESTO