E+H Conductivity compact device Smartec CLD134-PMV548AB1

$2,150.00

+ Free Shipping
  • Application

    Food, beverage, dairies, breweries and pharmaceutical industries, biotechnology

  • Characteristic

    Specifically intended for use in hygienic applications and especially suitable for following applications:
    Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring

  • 100 µS/cm to 2000 mS/cm
    Cell constant k : 6.3 1/cm

  • Measuring principle

    Inductive conductivity measurement

  • Design

    Hygienic design with FDA certified virgin PEEK body including all hygienic certifications

  • Material

    In contact with medium: Virgin PEEK

  • Process temperature

    Max. 125 °C (max. 257 °F)
    For sterilization: up to 150 °C for max. 60 min
    (up to 302 °F for max. 60 min)

  • Process pressure

    12 bar abs up to 90 °C
    (174 psi abs up to 194 °F)

  • Temperature sensor

    Pt 1000

  • Connection

    Dairy pipe, aseptic-fitting, Clamp ISO 2852, SMS-2″, Varivent N DN 40-125, Neumo Biocontrol D50

  • Ingress protection

    IP67

  • Output / communication

    Conductivity, concentration and temperature. 0/4 to 20 mA, HART, Profibus

  • Additional certifications

    FDA, EHEDG, 3A
    Biological reactivity USP class VI part <87> and <88>
    EC Regulation No. 1935/2004

SKU: 2005 Category: