E+H Radar measurement Time-of-Flight Micropilot FMR240-45E1AWJAC2B
$1,200.00
+ Free Shipping-
Measuring principle
Level radar
-
Characteristic / Application
Water & Wastewater (e.g. basins / channels / rivers / dams / lift stations / storm water basins / pump control)
Utility applications in all industries
Storage tanks -
Specialities
Bluetooth® commissioning,
Operation and maintenance SmartBlue App -
Supply / Communication
2-wire (HART, 4…20 mA, Modbus),
Bluetooth® wireless technology and App (optional) -
Frequency
K-band (~26 GHz)
-
Accuracy
+/- 2 mm (0,08″)
-
Ambient temperature
-40…+80°C (-40…+176°F)
-
Process temperature
-40…+80°C (-40…+176°F)
-
Process pressure / max. overpressure limit
-1…3 bar (-14,5…43 psi)
-
Main wetted parts
PVDF, PBT
-
Process connection
Thread:
G1″, NPT1″; G1 1/2″, NPT1 1/2″, G2″, NPT2″,
Flange:
UNI DN80….DN150 (3″…6″) -
Max. measurement distance
DN40: 15 m (49.2 ft),
DN80: 20 m (65.6 ft) -
Communication
4…20mA HART
Modbus
Bluetooth® wireless technology -
Certificates / Approvals
ATEX, CSA C/US, IEC Ex, NEPSI, EAC, JPN Ex, INMETRO
-
Options
Remote operation via SmartBlue App using Bluetooth®,
Remote HART indicator RIA15 in order structure,
Flooding protection tube,
Different mounting possibilities -
Application limits
FMR5x;
Ammoniacal gas phase:
FMR54 in stilling well;
Strong build-up formation:
FMR54 with air purge;
Only PTFE resistant:
FMR52;
Custody transfer measurement:
FMR5xx or NMR8x