  • Hermetically sealed Contite measuring https://heiautomation.com/cell with condensate-resistance, high reference accuracy: ±0.1%, optionally ±0.075% and minimum temperature effects thanks to active temperature compensation

  • Best batch-to-batch repeatabilityhttps://heiautomation.com/about/ and long-term stability

  • Modular concept for easy replacement of display or electronics

  • HistoROM/M-DAT data backup for instrument settings and measured values

  • Function-monitored from the measuring cell to the electronics

  • Seamless and independent system integration (HART/PA/FF)

  • International usage thanks to a wide range of approvals

  • The Deltapilot FMB70 https://www.youtube.com/@%E6%9B%BE%E6%85%A7%E5%A9%B7-z6jwith the condensate resistant Contite measuring cell and two-chamber housing is typically used in the process and hygienic applications. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. The integrated HistoROM/M-DAT https://heiautomation.com/contact-us-2/data module makes management of process and device parameters easy. Designed according to IEC 61508 for use in SIL3 safety systems.

    For level and/or pressure measurement.

    • Process connections: Threads, flanges and hygienic connections

    • Temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)

    • Measuring range: 0.1 to 10 bar rel. (1.5 to 150 psi)

    • Accuracy: ±0.075%

    • International explosion protection https://heiautomation.com/certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals

    • The Deltapilot FMB70 with the condensate resistant Contite measuring cell and two-chamber housing is typically used in the process and hygienic applications. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. The integrated HistoROM/M-DAThttps://heiautomation.com/ data module makes management of process and device parameters easy. Designed according to IEC 61508 for use in SIL3 safety systems.

      For level and/or pressure measurement.

      • Process connections: Threads, flanges and hygienic connections

      • Temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)

      • Measuring range: 0.1 to 10 bar rel. (1.5 to 150 psi)

      • Accuracy: ±0.075%

      • International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals